Power Top Problem

Short answer: The motor spinning freely after lifting partway is the classic low-fluid / leak symptom. If you see no puddles near the quarter panels or pump, it may just be slowly weeping seals — refill and purge the air. If there’s an obvious leak, fix it before refilling.

To purge: open the pump reservoir, disconnect the cylinder arms from the top, and run them up and down a few times to bring the air up to the reservoir; top off with fluid and close it, reconnect the arms, and grease the top’s joints. About a one-hour job.

Any proposed updates, changes, pictures, and/or corrections, please use our comment section below (may need to click on permalink to access comments feature). Information is subject to change and offered as is without any warranties or guarantees. Please review our Term's Of Use for more information.