Dealer Service Information Bulletin 68-I-73 – Diagnosing Air Conditioner Freon Loss on 1968 Models

Bulletin 68-I-73 — Pontiac Motor Division Dealer Service Information Bulletin, Section 1B, dated May 24, 1968. Attention: Service Manager.

Subject: Diagnosing Air Conditioner Freon Loss on 1968 Models.

Short answer: In the event of freon loss on any 1968 model, replace both “O” ring seals between the muffler fitting and compressor, install a new low-pressure hose, inspect the rest of the system, then evacuate and charge. Return the old hose and seals to the Pontiac F.E.W. Room.

Use the following procedure in the event of freon loss from the air conditioner system:

  1. Replace both “O” ring seals between muffler fitting and compressor.
  2. Install new low pressure hose (P.O.A. valve to compressor).
  3. Inspect (and correct) rest of system for loose clamps, fittings or ruptured high pressure hose.
  4. Evacuate and charge system and recheck for freon leak using standard procedure listed in Diagnosis Manual.

Parts Information — Use Only

Replacement Parts — A/C Freon Loss Repair
Part Name Part Number
Low Pressure (Suction) Hose (service hose should bear identification E.H.R. 3399) 3004948 [F-3]
Muffler Fitting to Compressor Seal Pkg. (5/Pkg.) (Dated after 5-1-68) 5887997 [ZAC]

Return hose and seals to the Pontiac F.E.W. Room.

Flat Rate and Warranty Information

Flat Rate Operations — A/C Freon Loss
Operation No. Operation Description Time
013-339 Replace suction hose .2
013-348 Replace “O” ring seals .2
Evacuate and charge 1.2

Use appropriate flat rate operation number if other items require service.

This is a transcription of the original dealer bulletin for easier reading and search. The complete original scan is shown below.

Content last modified: June 13, 2026 at 10:06 am


Categories: Dealer Technical Bulletins, Dealer Technical Bulletins - Section 01B -

← Frequently Asked Questions

Leave a Reply

Your email address will not be published. Required fields are marked *